The VIP series of Electrical transmitters are purposely designed for deep induced polarisation or Resistivity sounding investigations. The Vip injects a regulated current into the ground.
Predominantly used as part of mineral exploration studies, the VIP series include three systems with different power specifications. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers.
To simplify operation, the instrument manages the injection current and voltage automatically. When starting, the VIP automatically operates several safe tests to ensure that the device is not misused.
Table of contents
All VIP systems offer four operating modes:
- Time domain waveform, On Time (Ton) and Off time (Toff),
- Frequency domain waveform, outputting two user-selectable frequencies from 0.0625Hz and 4Hz.
- Dual frequency mode, a base frequency is selected from 0.0625 to 0.5Hz and the high frequency is fixed at 8 times the base frequency.
- Continuous mode, injects a constant DC current into the ground.
The VIP 4000 power makes it suitable for use in almost all geological formations. In situation where a wired synchronization is not possible, the VIP can be operated alongside the I-Fullwaver for accurate absolute time stamps when recording precise full waveform time domain measurements.
Softwares
Applications
Water ressources
- Locate conductive fault in fractured acquifere
- Assess water table characteristics
- Characterize salt water wedge extension in groundwater
Environment
- Monitor pollution
- Detect leaks and monitor degradation in waste disposal
- Locate and image buried structures
Natural hazard
- Detect and characterize cavities
- Assess landslide extension and volume
- Detect and locate clayey layers for geotechnical application
Mineral exploration
Characteristics
Transmitter | |
---|---|
Pulse duration | 500ms, 1s, 2s, 4s or 8s |
Output Power | 0 - 4000 W |
Output Voltage | 0 - 6000 Vpp |
Output Current | Regulated 0 - 5000 mA |
Resolution / Accuracy | 1 mA / 1% |
Frequency option | 0.0625Hz to 4Hz by factors of 2 |
Readings | Displays output current, output voltage, contact resistance and input power. |
Protection | Short circuits, thermal protection, Input overvoltage and under-voltage. |
Power requirements | 175 to 270VAC, 48-450Hz single-phase generator |
Dimensions | |
---|---|
( L x W x H ) | 32x24x41 cm |
Weight | 17Kg |